Bilge IQ features an input for a secondary float switch and an output for an external DC alarm to provide high-water and critical pump alerts:
2nd Float Switch Input:
Compatible with any standard 3rd-party float switch. When closed, it indicates critical water ingress (or, if enabled on dry-bilge setups, alerts every time the pump runs). It triggers a local alarm and broadcasts a secondary Alert PGN over the NMEA 2000 network.

External Alarm Connections:
-
-
NMEA 2000: Plug in our NAVAlarm NMEA 2000 Klaxon directly to the network for seamless power and data integration.
-
Direct DC Wiring: Connect an existing DC buzzer/alarm directly to the Bilge IQ Alarm output (open-collector transistor with a 350mA fuse).
-